The Power Profiler Kit II (PPK2) is operated in Ampere Meter mode for this
configuration.
Use a 4-pin cable for the pin connection between
PPK2,
nPM1304 EK, and the target device
(
nRF54L15
Development Kit (DK) in this example).
-
Connect the PPK2
GND to nPM1304 EK
GND. Depending on what you want to measure, use the following
alternatives on the EK:
-
VOUT1: use pin 3 or 4 on P4
-
VOUT2: use pin 3 or 4 on P5
-
Connect the PPK2
VIN to nPM1304 EK using the following
alternatives:
-
VOUT1: use pin 1 or 2 on P4
-
VOUT2: use pin 1 or 2 on P5
-
Connect the PPK2 to the target device (nRF54L15 DK in this example) on the following
pins:
- PPK2
VOUT to DK External supply
- PPK2
GND to DK External supply
-
Connect the PPK2 to a computer using a USB
cable.
-
Connect the nPM1304 EK to a computer using a USB cable.
-
Start the Power Profiler app.
-
Select your PPK2.
-
Select Ampere Meter as the mode.
-
Toggle Enable power output to power the target device
(nRF54L15 DK in
this example).
-
Click Start.