Instances
| Instance | Base address | Description |
|---|---|---|
| BOOST | 0x00000000 |
BOOST Registers |
Register overview
| Register | Offset | Description |
|---|---|---|
| TASKS_START | 0x20 |
Start tasks |
| VOUT | 0x22 |
Output voltage setting |
| VOUTSEL | 0x23 |
Output voltage set by pin or register |
| OPER | 0x24 |
Operating mode selection |
| COUNT | 0x25 |
Coil current pulse counter result in DPS mode |
| LIMIT | 0x26 |
Coil current pulse limiter setting in DPS mode |
| DPS | 0x27 |
Duration of DPS mode |
| GPIO | 0x28 |
GPIO and polarity selection for BOOST control |
| PIN | 0x29 |
GPIO usage for BOOST control |
| CTRLSET | 0x2A |
Enable VOUTMIN, VOUTWRN, VOUTDPS, OCP and VBATMINSEL |
| CTRLCLR | 0x2B |
Disable VOUTMIN, VOUTWRN, VOUTDPS, OCP and VBATMINSEL |
| IBATLIM | 0x2D |
Battery current limit setting |
| VBATMINLHSEL | 0x2E |
Enable register control for VBATMINL and VBATMINH comparator thresholds |
| VBATMINL | 0x2F |
Battery voltage threshold setting for VBATMINL |
| VBATMINH | 0x30 |
Battery voltage threshold setting for VBATMINH |
| VOUTMIN | 0x31 |
Output voltage threshold setting for VOUTMIN |
| VOUTWRN | 0x32 |
Output voltage threshold setting for VOUTWRN |
| VOUTDPS | 0x33 |
Output voltage threshold setting for VOUTDPS |
| STATUS0 | 0x34 |
Read operating mode |
| STATUS1 | 0x35 |
Status of output voltage |