TJ=-40°C to 105°C, VBAT=0.8 V to 3.4 V and TJ=25°C, VBAT=1.25 V for typical values (unless otherwise noted).
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| IQSHIP | Current consumption from battery in Ship mode | 35 | nA | ||
| IQBREAKTOWAKE | Current consumption from battery in Break-to-wake mode | 65 | nA | ||
| IQHIB | Current consumption from battery in Hibernate mode with TIMER running (VINT=1.8 V, LDOSW disabled) | 320 | nA | ||
| IQHIB_PT | Current consumption from battery in Hibernate Pass-through mode with TIMER running (VBAT=3 V, TJ=25°C, LDOSW disabled) | 175 | nA | ||
| IQULP | Current consumption from battery when BOOST is running in Ultra-Low Power mode, no load (VOUT=3 V, LDOSW disabled) | 300 | nA | ||
| IQLP | Current consumption from battery when BOOST is running in forced Low Power mode, no load (VOUT=3 V, LDOSW disabled) | 2.7 | µA | ||
| IQHP | Current consumption from battery when BOOST is running in forced High Power mode, no load (VOUT=3 V, LDOSW disabled) | 7.2 | mA | ||
| IQPT | Quiescent current, Pass-through mode (no load, OCP disabled) | 170 | nA | ||
| VBATCOLD_START | Battery voltage range, cold start (loaded voltage). The battery needs to be able to provide at least 10 mA (typ.) current during startup. | 0.8 | 3.4 | V | |
| VBATOVR | Battery voltage range, operating (loaded voltage) | 0.7 | 3.4 | V | |
| VBATPOR_RISING | Power-on reset rising threshold | 0.6 | V | ||
| VBATPOR_FALLING | Power-down reset falling threshold, VBAT domain | 0.5 | V | ||
| VINTPOR | Power-on reset rising, VINT domain | 2.2 | V | ||
| VINTBOR | Brown-out reset, VINT domain | 1.6 | V |