RF electrical specification

nRF93M1 Datasheet

TX power, RX sensitivity, and maximum input power at the nRF93M1 antenna port.

TX power

nRF93M1 operates at LTE Power Class 3 up to 23 dBm output power (nominal 23 dBm conducted).

RX sensitivity

Table 1. LABA RX sensitivity
Band Channel BW Min. Typ. Units
B1 5 MHz -99.5 -102 dBm
B3 5 MHz -97 -101 dBm
B5 5 MHz -100.5 -102 dBm
B7 5 MHz -99 -101 dBm
B8 5 MHz -101.5 -103 dBm
B20 5 MHz -100 -103 dBm
B28 5 MHz -100 -103 dBm
B38 5 MHz -100.5 -102.5 dBm
B40 5 MHz -100.5 -102.5 dBm
B41 5 MHz -100.5 -102.5 dBm

Production RF test support

For production-line RF characterization the nRF93M1 supports a non-signalling RF test mode via AT%RFTEST. The command supports single-tone transmit at 0–23 dBm and RSSI-based receive characterization across the supported bandwidth set (1.4, 3, 5, 10, 15, 20 MHz). The AT%PRODDONE command latches the production-complete flag after the test sequence.