Recommended operating conditions

nRF54L15 | nRF54L10 | nRF54L05 Datasheet

The operating conditions are the physical parameters that the device can operate within.

Table 1. Recommended operating conditions
Symbol Parameter Min. Nom. Max. Units
VDD VDD supply voltage 1.7 3.6 V
VDDEXT VDD supply voltage under extended operating temperature 1.7 3.4 V
VDDPOR VDD supply voltage needed during power-on reset 1.75 V
TA Operating temperature -40 25 85 °C
TAEXT Extended operating temperature 85 105 °C
TRST Recommended storage temperature 40 °C
RHRST Recommended storage relative humidity 90 %